Resource

Life Cycle Greenhouse Gas Emissions of Gastrointestinal Biopsies in a Surgical Pathology Laboratory

Cassandra Thiel
Cassandra Thiel • 18 January 2022

The biopsy process at a large academic pathology laboratory was grouped into steps. Each supply and reagent was catalogued and postuse treatment noted. Energy consumption was estimated for capital equipment. Two common scenarios were considered: 1 case with 1 specimen jar (scenario 1) and 1 case with 3 specimen jars (scenario 2).

Scenario 1 generated 0.29 kg of carbon dioxide equivalents (kg CO2e), whereas scenario 2 resulted in 0.79 kg CO2e—equivalent to 0.7 and 2.0 miles driven, respectively. The largest proportion of GHGs (36%) in either scenario came from the tissue processor step. The second largest contributor (19%) was case accessioning, mostly attributable to production of single-use disposable jars.

Resource author(s)
Gordon, I., Sherman, J. D., et al
Resource publishing organisation(s) or journal
American Journal of Clinical Pathology
Resource publication date
January 2022

Be the first one to comment