Access our full collection of sustainable healthcare resources, such as toolkits, case studies, publications and more. You can also add new resources to the library.
Sharing our newest publication in Society Of Critical Care Medicine JournalCritical Care Explorations: “Implementing a Green ICU Pathway Across a Large U.S. Health System.” Across 8 hospitals and 400+…
Published date
August 2026
•
by
Masud, F. N., Khan, A. H., Fischer, J. F., Estay, A. F., Gooch, M. E., Blackburn, L. M., Lozada, C., & Sasangohar, F
This study was conducted in the North East of England to determine the financial and environmental impacts of over-testing urine specimens within NHS laboratories.
Published date
July 2026
•
by
Isabel Garritt, Olivia Plumpton, William Roach, Emily Shaw, Sarah Walpole
Case study describing a water conservation programme in haemodialysis, focussing on reduced dialysate flow and high-recovery reverse osmosis, to achieve substantial water savings without compromising…
Published date
March 2026
•
by
Shah, M., Mohanty, M., Deppner, A., Vachharajani, T.
A recent federal lawsuit in the United States found that Johnson & Johnson's Biosense Webster unit hoarded used devices to interfere with hospital single-use device (SUD) remanufacturing programs,…
This study from Doncaster Renal Services evaluated reducing haemodialysis machine heat disinfection to once daily, instead of multiple cycles, to save energy and water. The team monitored infection…
Published date
May 2025
•
by
Poudyal, L., Long, L., Lockley, L., Choo, S., Kaki, S.
This Bradford study targeted pharmaceutical waste in haemodialysis as a way to reduce both carbon emissions and costs. Through closer oversight of prescribing, stock control, and prioritisation of use…
Published date
May 2025
•
by
Bajet, L., Orlando, A., Bismillah, S., Ibrahim, K., Choo, S., Lockley, L., Stoves, J.
This Leeds study evaluated switching haemodialysis acid concentrate from 1:34 to 1:44 dilution to reduce environmental impact. By using a more concentrated solution, each canister produced more…
Published date
May 2025
•
by
Matusaitiene, J., Jones, P., Simpson, T., Choo, S., Lockley, L., Wright, M., Gullapudi, L.
This project from Bradford renal services evaluated reducing the frequency of haemodialysis machine heat disinfections to cut energy and water use. Heat disinfection is essential for safety but is…
Published date
May 2025
•
by
Orlando, A., Bajet, L., McCarthy, J., Choo, S,. Lockley, L., Stoves, J.
This study presents the carbon footprint of the In-Centre Haemodialysis (ICHD) patient pathway in Sheffield Teaching Hospitals, mapping emissions across key stages of treatment. It highlights the…
This study outlines a quality improvement project assessing the impact of reducing dialysate flow rates in haemodialysis from 800 ml/hr to 500 ml/hr. The change was introduced to cut water and energy…
Published date
October 2024
•
by
Whyke, K., Sabharwal, A., Anderson, K., Spark, P., Lockley, L., Choo, S., Reddy, V.