Access our full collection of sustainable healthcare resources, such as toolkits, case studies, publications and more. You can also add new resources to the library.
This study was conducted in the North East of England to determine the financial and environmental impacts of over-testing urine specimens within NHS laboratories.
Published date
July 2026
•
by
Isabel Garritt, Olivia Plumpton, William Roach, Emily Shaw, Sarah Walpole
This study from Doncaster Renal Services evaluated reducing haemodialysis machine heat disinfection to once daily, instead of multiple cycles, to save energy and water. The team monitored infection…
Published date
May 2025
•
by
Poudyal, L., Long, L., Lockley, L., Choo, S., Kaki, S.
This Bradford study targeted pharmaceutical waste in haemodialysis as a way to reduce both carbon emissions and costs. Through closer oversight of prescribing, stock control, and prioritisation of use…
Published date
May 2025
•
by
Bajet, L., Orlando, A., Bismillah, S., Ibrahim, K., Choo, S., Lockley, L., Stoves, J.
This Leeds study evaluated switching haemodialysis acid concentrate from 1:34 to 1:44 dilution to reduce environmental impact. By using a more concentrated solution, each canister produced more…
Published date
May 2025
•
by
Matusaitiene, J., Jones, P., Simpson, T., Choo, S., Lockley, L., Wright, M., Gullapudi, L.
This project from Bradford renal services evaluated reducing the frequency of haemodialysis machine heat disinfections to cut energy and water use. Heat disinfection is essential for safety but is…
Published date
May 2025
•
by
Orlando, A., Bajet, L., McCarthy, J., Choo, S,. Lockley, L., Stoves, J.
This study presents the carbon footprint of the In-Centre Haemodialysis (ICHD) patient pathway in Sheffield Teaching Hospitals, mapping emissions across key stages of treatment. It highlights the…
Project completed as part of the National 2024-25 Green Maternity Challenge by the Great Western Hospitals NHS Foundation Trust team.Team members:· Zoe Daggatt-Powrie, Clinical Sustainability Fellow·…
This study outlines a quality improvement project assessing the impact of reducing dialysate flow rates in haemodialysis from 800 ml/hr to 500 ml/hr. The change was introduced to cut water and energy…
Published date
October 2024
•
by
Whyke, K., Sabharwal, A., Anderson, K., Spark, P., Lockley, L., Choo, S., Reddy, V.
Project completed as part of the 2024/25 RUH Bath Green Team Competition.Team members:Sian Griffiths, Consultant Radiographer Urology Specialist, Hazel Clarke, Macmillan Radiotherapy Late Effects…
Published date
February 2025
•
by
Sian Griffiths, Consultant Radiographer Urology Specialist, Hazel Clarke, Macmillan Radiotherapy Late Effects Radiographer
Grimsby dialysis unit partnered with Kidney Quality Improvement Partnership (KQIP) and the Trying to Reduce UnNecessary Carbon from Haemodialysis (TRUNC-HD) initiative to cut carbon emissions by…